Inside the Household Distribution Board (Main Switch, RCD & MCBs)
Everything electrical in a house is fed from one distribution board on the wall. Power enters through the double-pole main switch, passes through a 30 mA RCD life-safety monitor onto a copper busbar, and branches out through individual trip switches (MCBs) sized for each room's cable.
At 230 V, a 3 kW kitchen kettle draws 13.0 A and a 2 kW water heater draws 8.7 A. Change the country voltage in Settings (100 V to 240 V) and watch every branch current recalculate live!
- The Main Switch isolates the entire house by cutting both Live (brown) and Neutral (blue) conductors simultaneously.
- Each circuit takes only the current its appliances draw (I = P ÷ V), while the main switch carries all branch currents added together.
- Pressing the yellow 'T' button on the RCD simulates a tiny earth leak to verify the mechanical trip mechanism works.
| Symbol | Component | Real-World Engineering Tip |
|---|---|---|
| SW_MAIN | Double-Pole Main Switch (100A Isolator) | Always flip the Main Switch OFF and verify with a voltage tester before touching any busbar inside a consumer unit. |
| RCD1 | 30 mA RCD (Residual Current Device) | Press the yellow 'T' (Test) button quarterly to prevent the internal mechanical latch from seizing up over years. |
| MCB1–4 | MCB Trip Switches (B32 / B20 / B16 / B6) | Never replace a B6 lighting breaker with a B32 breaker — the thin 1.5 mm² lighting wire would melt before a 32A breaker trips! |
| N / PE | Neutral Bar (N) & Earth Bar (PE) | Loose neutral bar screws cause high-resistance arcing and flickering lights across the house. |
Real-World Bench Scenario: Homeowner Pitfall: Confusing an MCB trip (overload/short on one branch) with an RCD trip (earth leakage anywhere on the shared neutral bar that kills half or all of the board).
Bench Challenge: Click individual breakers (B32, B20, B16, B6) directly inside the distribution board, press the yellow 'T' test button on the RCD, and switch between 120V and 230V mains.