Will the Extension Lead Take It? Multi-Socket Overload Simulator
A four-way extension lead gives you four sockets, but all four share ONE flexible cord and ONE wall plug rated at 13 A or 16 A. Plugging a kettle (2.2 kW), heater (2.0 kW), and toaster (1.2 kW) into the same strip pulls over 23 A at 230 V — overheating the cord by I²R until the thermal breaker trips or insulation melts.
At 230 V, a 13 A extension lead maxes out at 2,990 W (16 A maxes out at 3,680 W). Turning on a 2,200 W kettle + 2,000 W heater demands 4,200 W (18.3 A) — instant overload!
- Parallel appliances add their currents together in the shared extension cord: I_cord = I_kettle + I_heater + I_toaster + I_lamp.
- Cord heating grows with the SQUARE of current (P_heat = I² × R_cord): doubling current quadruples the heat trapped inside the cable!
- In 120 V countries (USA/Canada), the same 2,000 W heater draws nearly twice the current (16.7 A) compared to 230 V (8.7 A)!
| Symbol | Component | Real-World Engineering Tip |
|---|---|---|
| CORD | Shared Flexible Mains Cord (1.25–1.5 mm²) | Feel the cord after 5 minutes of heavy load — if it feels warm to the touch, unplug high-wattage heaters immediately. |
| SW_OVL | Thermal Overload Reset Switch (13 A / 16 A) | Cheap unbranded multi-plug adapters often omit the thermal breaker entirely, creating a severe house-fire hazard. |
Real-World Bench Scenario: Never run high-wattage heating appliances through a coiled-up extension reel! Coiled cable traps I²R heat like an inductor oven and melts its PVC jacket at half its unwound rating.
Bench Challenge: Click each appliance socket on the power strip to switch on the Kettle, Heater, and Toaster together, then switch mains voltage to 120 V in Settings to see how much faster it overloads.